9 research outputs found

    Frequency drift in MR spectroscopy at 3T

    Get PDF
    Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B-0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC).Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p &lt; 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI.Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.</p

    RELATIVE DOSING OF PHOSPHATE BINDERS FOR EFFECTIVE MANAGEMENT OF PHOSPHATE AND PROTEIN INTAKE IN CHRONIC KIDNEY DISEASE

    Get PDF
    Patients with chronic kidney disease undergoing haemodialysis have a maximum recommended dietary phosphate (P) intake of 1000 mg/day and a recommended protein intake of 1.2 g/kg/day. Achieving this level of protein intake is associated with the best patient outcomes. However, protein-containing foods also contain P, and elevated serum P is associated with increased all-cause mortality. It is therefore important to manage the levels of serum P while maintaining adequate levels of nutrition. For different P binders, we estimated the dose and associated tablet burden needed to remove excess P based on the maximum recommended daily P intake. We also examined the implications for patient nutrition. Published binding capacities of different P binders in healthy volunteers ingesting up to 2000 mg/day P, are in the range of 26–135 mg P/g binder. Assuming that 60% of ingested P is absorbed, and that haemodialysis three-times weekly will remove 2400 mg P, a haemodialysis patient ingesting 1000 mg/day P will have a residual P burden of 257 mg/day. To bind this, patients would require a maximum of 3 x 1000 mg lanthanum carbonate tablets, or approximately 9 x 400 mg calcium carbonate tablets, or approximately 9 x 800 mg sevelamer hydrochloride tablets. The recommended protein intake for a 70 kg haemodialysis patient is 84 g/day. A realistic estimate of the average P content of a typical diet is 15 mg/g protein, which equates to a P intake of 1260 mg/day. This is considerably in excess of the recommended limit and, depending on vitamin D status more than 60% may be absorbed, further adding to the residual P burden. The availability of binding capacity data for P binders, presents physicians with the possibility of tailoring doses of binder to a patient’s diet, facilitating sufficient intake of dietary protein while maintaining a neutral P balance. Use of high-capacity binders, such as lanthanum carbonate, would minimize the tablet burden faced by patients and this may also encourage adherence

    PHOSPHATE BINDER THERAPY AND SERUM PHOSPHATE CONTROL FOLLOWING INITIATION OF HAEMODIALYSIS

    Get PDF
    Hyperphosphataemia is associated with increased all-cause mortality in patients with chronic kidney disease (CKD), but serum phosphate (P) levels can be managed by dialysis, diet and the use of P binders. Serum P data were obtained retrospectively from a US dialysis provider for the 9 months following initiation of haemodialysis (HD) in CKD patients, who were then grouped according to the variations in their serum P. Group baseline characteristics and changes in P binder use over time were described. Variations in average monthly serum P values from months 4 to 9 were classified as either consistently in the target range (CT, 3.5–5.5 mg/dL), consistently low (CL, < 3.5 mg/dL), consistently high (CH, > 5.5 mg/dL), or varying between the low and target (LT), target and high (TH) or the low and high ranges (LH). For each group, baseline characteristics and changes in P binder use during the study were compared with CT (the reference group) to identify differences. In total, 47742 eligible patients were allocated to the six groups: CT, 7301; CL, 131; CH, 5001; LT, 6469; TH, 24469; LH, 4371. CH, TH, and LH were significantly younger than CT, with fewer comorbidities, higher incidence of elevated parathyroid hormone (PTH) and higher mean serum P; CH and TH also had higher levels of P binder use. CL and LT were older, with more comorbidities, lower PTH levels and lower levels of P binder use than CT. Overall, comparing months 8–9 with baseline (months 1–3), more patients received P binder therapy (51.7 vs 35.0%), on a larger percentage of days (50.0 vs 30.9%), but with little change in mean serum P (5.3 vs 5.2 mg/dL). By group, mean serum P increased numerically in CH (7.5 vs 6.6 mg/dL) and TH (5.6 vs 5.4 mg/dL) but decreased in other groups. Serum P can be difficult to control following initiation of HD. Patients with elevated serum P were younger, and most had higher P binder use than the reference group. Overall, binder use was lower than in other studies of HD patients. Dietary education and higher doses of the most effective P binders may be needed to improve P management

    An archipelagic literature: re-framing ‘The New Nature Writing’

    No full text
    This paper proposes a reconsideration of ‘The New Nature Writing’ as an archipelagic literature, a literature concerned with the diverse and distinctive cultures of Britain and Ireland as much as with its nature. It interrogates the term ‘nature writing’ as applied to this recent literary movement and outlines some differences between this and ‘place writing’. It also traces the influence of archipelagic criticism on this recent movement, exploring some common ground between devolutionary and environmental politics. Finally, it proposes that the archipelagic perspective offers a potentially quite useful means of thinking through some recent debates around the status of place in a modern, global environment

    Frequency drift in MR spectroscopy at 3T

    No full text
    Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B-0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites. Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC). Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI. Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed

    Frequency drift in MR spectroscopy at 3T

    No full text
    Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B 0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites. Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC). Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI. Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed
    corecore